            BOLT & SHIELD ANCHORS





               SNAKE+   ™      Internally Threaded Screw Anchor For Use With Strength Design

                             The SNAKE+ overhead anchor speeds installation of  The patented proprietary anchor eliminates the time consuming steps of
                                      ™
                             threaded rods and is one of the industry’s first   banging in a drop-in and using a special tool to set the expansion mechanism.
                             mechanical anchors to meet the  new more stringent  It is simply set into a drilled hole, tightened with a 1/2” impact wrench until
                             International Building Code (IBC) for strength design  flush with the ceiling and ready for the insertion of threaded rod. There is no
                             (Cracked Concrete).                       need to swing a heavy hammer overhead while on a ladder or lift.


               SNAKE+   ™                                               APPROVALS & LISTINGS
               Carbon Steel Anchor, Zinc Plated                        • International Code Council, Evaluation Service (ICC-ES), ESR-2272 for concrete. Code compliant with the
                                                                        2015 IBC, 2015 IRC, 2012 IBC, 2012 IRC, 2009 IBC, 2009 IRC, 2006 IBC, and 2006 IRC.
                                                                       • Tested in accordance with ACI 355.2 and ICC-ES AC193 for use in structural concrete under the design
                                                                        provisions of ACI 318 (Strength Design method using Appendix D)
                                                                       • Evaluated and quali ed by an accredited independent testing laboratory for recognition in cracked and
              ITEM       ROD/ANCHOR               MIN HOLE            THREAD             BOX             CARTON
              CODE       SIZE     DEPTH                  DEPTH  QTY.              QTY.  uncracked concrete including seismic and wind loading (Category 1 anchor)
              POW 6400SD             1/4"  2"                    22/32"        100      1000  • Evaluated and quali ed by an accredited independent testing laboratory for reliability against brittle
              POW 6401SD             3/8"  1-5/8"            11/16"       50            500  failure, e.g. hydrogen embrittlement
              POW 6403SD  1/2"   2-1/2"            29/32"        50       300  • Evaluated and quali ed by an accredited independent testing laboratory for supplemental recognition
                                                                        in redundant fastening applications
                                                                       • FM Global (Factory Mutual) - File No. 3038104 (see report for sizes) www.approvalguide.com - Pipe
                                                                        hanger components for automatic sprinkler systems
                        ™
               SNAKE+ ANCHOR
               Setting Tools
                                                                        INSTALLATION SPECIFICATIONS

              ITEM       DESCRIPTION              BOX                   Anchor Property/                                      Units                                          Norminal Anchor  Size
              CODE                                QTY.                  Setting Information           1/4     3/8                1/2
              POW 6402SD       1/4" Hex Adapter with Hex Driver End             1  Nominal outside anchor diam.                  in.                       0.375 0.500                       0.750
              POW 6407SD       3/8" Hex Adapter with Hex Driver End             1           (mm)   (9.5)       (12.7)                      (19.1)
              POW 6404SD       1/2" Hex Adapter with Hex Driver End             1  Internal thread diameter (UNC)  in.  0.250  0.375  0.500
                                                                                            (mm)   (6.4)       (9.5)    (12.7)
                                                                        Drill bit diameter dbit   in.   3/8    1/2      3/4
              INSTALLATION                                                                         ANSI        ANSI     ANSI
                                                                        Minimum hole depth  in.    2           2        2-1/2
                                                                                            (mm)   (51)        (51)     (64)
                                                                        Minimum concrete    in     3           4        4
                                                                        member thickness    (mm)   (76)        (102)    (102)
                                                                        Overall anchor length   in.  1-1/4     1-1/4    1-11/16
                                                                                            (mm)   (32)        (32)     (43)
                                                                        Nominal embedment depth  in.  1-5/8    1-5/8    2-3/16
                                                                                            (mm)   (41)        (41)     (55)
                                                                        Effective embedment   in.  Not Applicable   1.10  1.54
                                                                                            (mm)               (28)     (39)
                                                                        Minimum edge distance  in.  Not Applicable  3   4
                                                                                            (mm)               (76)     (102)
                                                                        Minimum spacing distance  in.  Not Applicable   3  4
                                                                                            (mm)               (76)     (102)
                                                                        Critical edge distance  in.  Not Applicable   3  4
                                                                                            (mm)               (76)     (102)
             Using the proper Select a powered Drive the anchor Insert threaded  Maximum impact   ft.-lb.  120  345     345
             drill bit size,   impact wrench  into the hole until rod or a bolt into  wrench power (torque)  (N-m)  (163)  (468)  (468)
             drill a hole   that does not   the        the Snake+,      Maximum tightening torque  ft.-lb.  4  14       36
             into the base  exceed the   shoulder of the  taking care not  of steel insert element  (N-m)  (6)  (19)    (49)
                                                                        (threaded rod or bolt)
             material to the  maximum    Snake+setting  to exceed the
             required depth.  torque, for the  tool comes into  maximum  1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D.
             The tolerances  selected anchor  contact with the specified tighten-
             of the carbide  diameter. Attach  surface of the  ing torque of the
             drill bit used  the Snake+   base material.  steel insert
             should meet the setting tool to  Do not spin the  element. Min.
             requirements of  the impact  setting tool off  thread engage-
             ANSIStandard  wrench. Mount  the anchor to  ment should be
             B212.15.      theanchor onto  disengage.  at least one
                           the setting tool.           anchor diameter.
                                                                                                                             107
                                                 www.shoptanner.com         email: sales@tannerbolt.com        800 456-2658
                                                 714 Montauk Ave., Brooklyn,  NY 11208    718 434-4500   Fax: 718 434-3215
                                                 60-01 55th Drive, Maspeth, NY 11378    718 786-2050   Fax: 718 228-7297
                                                 800 3rd Ave., Brooklyn, NY 11232    929 337-1821
   110   111   112   113   114   115   116   117   118   119   120