Page 19 - Tanner Fasteners & Industrial Supplies Biig Book
P. 19

Fasteners 8_17.qxp_Layout 1  8/18/17  11:55 AM  Page 11

            SELF-DRILLING SCREWS





              SELF-DRILLING X METAL SCREWS

              Fastening to Metal
              Common Applications:
              • Steel decking to structural steel           Self-Drilling X Metal Screws     Bulk Cartons
              • Steel stitching (“side-lap” stitching)      ITEM  CODE                                          SHANK    LENGTH      THREADS   POINT    DRILL-THROUGH     FINISH                 CARTON     APPLICATION(S)
                                                                         SIZE IN    IN                 IN  PER INCH   SIZE        THICKNESS         QTY.
              • Cold-formed steel framing                   SIM XQ1B1016-4K*  10   1  16  3  .110 – .175 Quik Guard 4000 Steel stitching, cold
                                                                                                          }
              Features & Benefits:                          SIM XQ1B1214-3.5K*  12   1   14   3   .110 – .210 Quik Guard  3500   formed steel framing
                                                            SIM XQ78B1224-3K*  12   7/8   24   4   .110 – .250  Quik Guard  3000
              • 5/16" hex head                              SIM XQ114B1224-2.5K* 12   1-1/4  24   5   .125 – .500  Quik Guard  2500  } Steel decking to structural steel,
                                                                                                            cold formed steel framing
              • Drill point                                 SIM XQ112B1224-2K*  12   1-1/2  24   5   .125 – .500 Quik Guard  2000
              • Hex washer head                             SIM XU34B1016-5K  10   ¾   16   1   .030 – .110  Clear Zinc  5000
                                                                                                          }
              Codes/Standards:                              SIM X34B1016-5K  10   ¾   16   3   .110 – .175  Clear Zinc  5000   Steel stitching, cold
                                                            SIM X1B1016-4K  10   1   16   3   .110 – .175  Clear Zinc  4000   formed steel framing
              ICC-ES ESR-3006 (excludes XU34B1016-5K); IAPMO UES   SIM X1B1214-3.5K  12   1   14   3   .110 – .210  Clear Zinc  3500
                                                                                                          }
              ER-326; City of L.A. RR25670 (1" length sizes only) &  SIM X114B1224-2.5K  12   1-1/4  24   5   .125 – .500  Clear Zinc  2500  Steel decking to structural steel,
                                                                                                            cold formed steel framing
              RR25917 & RR26009; ASTM C1513 compliant; Factory
                                                           * These coated fasteners possess a level of corrosion resistance that makes them suitable for use in some exterior and corrosive
              Mutual (FM) Approval 3045651; SDI DDM03-Appendix VII
                                                           environments and with some preservative-treated woods. For applications in higher-exposure applications, consider Type-300
                                                           series stainless-steel fasteners for superior corrosion resistance.
                                                           WARNING: Industry studies show that Clear Zinc hardened fasteners can experience performance problems in wet or
                                                           corrosive environments. Accordingly, use this product in dry, interior, and noncorrosive environments only







                                                                                         ®
              Quik Drive Collated Metal Screw               Self-Drilling X Metal Screws     Quik Drive Collated
                        ®
                                                            ITEM  CODE                                    SHANK LENGTH      THREADS     POINT   FINISH                      CARTON                 APPLICATION(S)
              Common Applications:                                      SIZE  IN IN                PER INCH     SIZE                                           QTY.
                                                            SIM XQ1S1016*   #10       1              16  3  Quik Guard  1500        Steel stitching, cold formed steel framing
              • Steel decking to structural steel
                                                            SIM XQ1S1214*   #12   1   14   3  Quik Guard 1500  Steel stitching, cold formed steel framing
              • Steel stitching (“side-lap” stitching)      SIM XQ78S1224*   #12   7/8   24   4  Quik Guard 1500    Steel decking to structural steel,
              • Cold-formed steel framing                   SIM XQ114S1224*   #12   1-1/4  24   5  Quik Guard 1500    }  cold formed steel framing
                                                            SIM XQ112S1224*   #12        1-1/2  24   5  Quik Guard 1500
              Features & Benefits:
                                                            SIM X1S1016  #10   1  16   3  Clear Zinc   1500  Steel stitching, cold formed steel framing
              • 5/16" hex head
                                                            SIM X1S1214  #10   1  14  3  Clear Zinc   1500  Steel stitching, cold formed steel framing
              • Drill point                                 SIM X114S1214  #12   1-1/4  24  5  Clear Zinc   1500  Steel decking to structural steel,
              • Hex washer head                                                                       cold formed steel framing
              • Straight collation
              Codes/Standards:                              Quik Guard® Coatingis a proprietary coating consists of an electrodeposited base layer
                                                            with organic paint layer that provides equivalent protection to hot-dip galvanization in some
              ICC-ES ESR-3006, City of LA RR25670 and RR25917, ASTM
                                                            exposures. In ASTM B117 salt spray test at 1000 hours of exposure, Quik Guard coating has an
              C1513 compliant, FM Approval #3045651, SDI DDM03,
                                                            average 1.9% red rust.
              Appendix VII, IAPMO-UES ER-326

















                                                                                                                             11
                                                 www.shoptanner.com         email: sales@tannerbolt.com        800 456-2658
                                                 714 Montauk Ave., Brooklyn,  NY 11208    718 434-4500   Fax: 718 434-3215
                                                 60-01 55th Drive, Maspeth, NY 11378    718 786-2050   Fax: 718 228-7297
                                                 800 3rd Ave., Brooklyn, NY 11232  929 337-1821
   14   15   16   17   18   19   20   21   22   23   24