Page 254 - Tanner Fasteners & Industrial Supplies Biig Book
P. 254

SafetyCat_2_17.qxp_Layout 1  8/18/17  1:34 PM  Page 246


                                                                            FIRE EXTINGUISHERS





               • Deploy the right fire extinguisher for the job.        POSTING OF FIRE EXTINGUISHERS
               • Not all fire extinguishers are the same.
        SAFETY  • Use ABC type fire extinguishers on the jobsite.       • Mount in work trucks
                                                                        • Mount on jobsite machines like boom lifts, scissor lifts, forklifts and
               • Class ABC fire extinguishers can extinguish three classes of fire:
                                                                         trailer mounted welders
               • Class A: Ordinary combustibles like lumber, paper, cardboard,   • Post during hot work–grinding, welding, brazing
                      natural cover                                     • Post within 30 feet of torches used in roofing
               • Class B: Flammable & combustible liquids: cooking oil, gasoline, chemicals  • Post in maintenance areas
               • Class C: Energized electrical equipment like computers and electric motors • Refer to OSHA & NFPA fire extinguisher posting guidelines.



               DRY CHEMICAL
                                                          Size/Model     5 ABC       5 ABC V/B   10 ABC TALL   20 ABC
            • Monoammonium Phosphate based dry chemical agent.
            • Rated for use on “A”, “B”, and “C” class fires. Provides the   Part No. Alum Valve BUC 10914/TAG BUC 25614/TAG BUC 11340/TAG  BUC 12120/TAG
             widest, most practical range of fire protection.  Capacity lbs/kg   5 / 2.27  5 / 2.27  10 / 4.54   20 / 9.07
            • Rechargeable                                U.L. Rating    3A: 40B:C   3A: 40B:C   4A: 80B:C    20A: 120B:C
            • Steel cylinders with a baked-on polyester enamel coating   Ship Wt. Alum Valve 9.5 / 4.3  9.75 / 4.4  17.25 / 8.1   33 / 15.0
             stand  up to harsh environments.             Height (in/cm)  16.375 / 41.6  16.375 / 41.6  21 / 53.3   21.25 / 53.8
                                                          Width (in/cm)  7.25 / 18.4  7.25 / 18.4  7.75 / 19.7   8.25 / 22.2
            • Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.
                                                          Diameter (in/cm)   4.25 / 10.8  4.25 / 10.8  5.125 / 13.0   7.5 / 19.1
                                                          Bracket        Wall        Veh / Marine  Wall       Wall
                                                          Range (Feet/Meters) 12-18/3.7-5.5  12-18/3.7-5.5  15-21/4.6-6.4   15-21/4.6-6.4
                                                          Discharge Times sec.  14   14          22           26
                                                          Operating Pressure 195PSI/1340 kPa 195PSI/1340 kPa 195PSI / 1340 kPa 195PSI / 1340 kPa
                                                          Cylinder       Steel       Steel       Steel        Steel
                                                          • Extinguishers sold tagged or untagged



                                                                            fire protection
             5 ABC                             5 ABC V/B                    10 ABC TALL                     20 ABC


              AUTOMATIC SPOT PROTECTION                   Mount Style:           Vertical          Horizontal
              Vertical & Horizontal Mount
                                                          Part No.        BUC 81001/TAG  BUC 82001/TAG  BUC 81021/TAG  BUC 82021/TAG
             • Designed to provide supplemental  protection
                                                          Capacity lbs/kg  10 lbs./4.5 kg  20 lbs./9.1 kg  10 lbs./4.5 kg  20 lbs./9.1 kg
              suitable for some local and total flood
                                                          Ship Wt. lbs/kg  19 lbs./8.6 kg  36 lbs./16.3 kg  19 lbs./8.6 kg  36 lbs./16.3 kg
              applications                                Operating Pressure 195 psi  195 psi      195 psi       195 psi
             • Two mount styles available, charged with   Length          17.625 in.  21.875 in.   20.875 in.    21.875 in.
              multipurpose dry chemical (ABC)             Diameter        6.0 in.     7.5 in.      5.125 in.     7.5 in.
             • Cylinders are constructed and tested to the     Max. Total
              same engineering standards as portable        Flood Volume  1300 cu feet  2184 cu feet  1300 cu feet  2184 cu feet
              extinguishers                               Max. Total
             • Units are not Underwriters Laboratories Listed  Flood Height
                                                            Above Hazard  13 ft.      14 ft.       13 ft.        14 ft.
              and are not  intended  for use in lieu of an
                                                          Local Application-
              engineered system
                                                            Coverage Areas  10 ft. x 10 ft.  12 ft. 13 ft.  10 ft. x 10 ft.  12 ft. 13 ft.
             • They are not to be
                                                          Mounting Brackets  700226   700226       700229        700229
              multiple mounted
                                                          • Extinguishers sold tagged or untagged
       246
           800 456-2658         email: sales@tannerbolt.com        www.shoptanner.com
                                   714 Montauk Ave., Brooklyn,  NY 11208    718 434-4500   Fax: 718 434-3215
                                    60-01 55th Drive, Maspeth, NY 11378    718 786-2050   Fax: 718 228-7297
                                                     800 3rd Ave., Brooklyn, NY 11232  929 337-1821